Great,The "product upgrade" happens to hit the core change points of GB 7793-2025.
I. Upgrade objectives
Make blackboard lighting fixtures "naturally comply with"
"In ordinary classrooms using multimedia teaching, each blackboard lighting fixture shall be equipped with an independent dimming or illuminance-reduction control device"
II. The 5 "hard indicators" of the product upgrade (must be achieved)
① Each fixture ≠ each row of fixtures (this is the lifeline)
Upgrade requirements:
- Each blackboard fixture:
- Independent dimming
- Or independent illuminance reduction
Acceptable approaches:
- Single-fixture built-in dimming driver
- Single-fixture independent circuit
- Single-lamp addressable control
Not recommended / risky:
- One row of lights shares a single dimming channel
- The left and right lamps are always synchronized and cannot be separated
👉 At minimum, ensure: left / right writing board lights can be dimmed independently
② The dimming "form" is not mandatory, but the "effect" must be obvious
The standard keywords are:
"dimming or reducing illuminance"
Three recommended reliable solutions (from easy to advanced)
| Solution | Description | Acceptance risk |
|---|---|---|
| Two-level illuminance reduction | 100% / ≤50% | ⭐ Lowest |
| Three-level dimming | 100% / 70% / 30% | ⭐⭐ |
| Continuous dimming | 1–100% | ⭐⭐⭐ (Best) |
👉 The key point is not showing off, but "being able to visibly dim"
③ Dimming must be "controllable on site" (not via backend)
Strongly recommend upgrading to:
- Wall-mounted dimming panel
or - Wall-mounted independent buttons (High / Low)
Not recommended to claim separately:
- Can only be adjusted via backend system
- Can only use APP (easily questioned during acceptance)
👉 The question experts love to ask most:
"Can the teacher adjust it directly while standing at the podium?"
④ Dimming must be "flicker-free" (this is the hidden minefield of 2025)
When upgrading, must simultaneously changeDriver power supply:
Minimum requirement recommendation:
- Above visible flicker frequency
- Or constant current + high-quality dimming solution
Usable wording for product copy:
- "No visible flicker during dimming"
- "Complies with classroom healthy light environment requirements"
👉 Otherwise:
Dimmed the light, flicker exceeds standard = upgrade failed
⑤ Default "multimedia mode" is a bonus (not mandatory, but very worthwhile)
Recommended product logic:
- Power-on defaults to 100%
- One-touch switching:
- ▶ Blackboard mode
- ▶ Projection mode (automatic illuminance reduction)
This is very popular in reviews, but not mandatory.
III. Product structure upgrade recommendations (engineering-executable)
🔧 Option A | Traditional and reliable type (high cost-effectiveness)
- Writing board lights ×2 (or more)
- Each light independently driven
- Two-level wall control (high / low)
- Independent circuit
👉 Easiest to pass acceptance
🔧 Option B | Mainstream upgrade type (recommended)
- Single-lamp stepless dimming driver
- Knob / touch panel
- Independent addresses for left and right lights
- One-touch illuminance reduction in projection mode
👉 Both standard response and user experience are good
🔧 Solution C | Smart Advanced Type (High-end)
- Single-lamp addressing
- Dual control via local panel + smart system
- Scene memory
- Usable when network is down
👉 Note:
Be sure to retain "local control"
IV. After the upgrade, you can legally and confidently promote it this way
✅ One-sentence product selling point
Blackboard lighting fixtures supportindependent dimming/illuminance reduction control per lamp, suitable for multimedia teaching scenarios, and compliant with the new GB 7793-2025 standard requirements.
✅ Technical parameters can be stated as
- Dimming method: independent dimming per lamp / illuminance reduction control
- Control method: local panel control
- Applicable standard: GB 7793-2025 (blackboard lighting clauses)
V. The 6 most common pitfalls in upgrades (must avoid)
❌ "One dimming for a whole row of lights"
❌ Only on/off
❌ Obvious flicker after dimming
❌ No wall control
❌ Reliance on a backend system
❌ Can be claimed, but cannot be delivered on site